High Power Busbar Systems (400A / 6300A)
The Smartest Way to Distribute Power
HP-K SERIES

GENERAL FEATURES
Busbar trunking systems are sandwich systems compatible with complex low voltage energy distribution lines. Feeder and Plug-in types allow easy attachment to each other. They provide efficiency in low voltage distribution systems in industrial and commercial applications. Feeder and plug-in are produced with aluminum or copper conductors from 400 amps to 6300 amps. In the 3-pole or 4-pole full neutral configuration, the operating voltage is 1000 V. Standard production 3P+N+PE body grounding is 50% of the phase conductor. The case is produced as Aluminum. Standard production IP 55, IP 65 can be produced upon request.

General
It is used in places with high current requirements such as between transformer and panel, high service buildings, commercial centers, industrial facilities, military facilities, public buildings.

Sandwich Construction
Feeder and Plug-in busbars are sandwich type systems that are easy to assemble. Due to its structure, the voltage drop characteristics are at minimum and it provides a regular low reactive power factor. Construction channels are designed as aluminum profile and upper and lower covers are aluminum. Hysteresis currents and Eddy currents are minimized by spreading them in the aluminum channel. In cases where 2 or 3 conductors are used per phase in Feeder and Plug-in lengths, parallelization is made at the end of each phase. (In the change of phases). The body of the plug-in lengths has windows with lids that allow flat mounting and exit of tap-offs. Additional accessories used for the feeder can also be used in Plug-in types. Plug-in and Feeder types can be mounted together.

Full Enclosed Construction
Busbar systems have a fully closed design. This duct design does not reduce the electrical values and since there are no ventilation holes, the contact of the conductors with a foreign material is prevented. The heat dissipation spreads directly with the body close to the conductors.

Finish
RAL 7038
Electrostatic paint is applied in busbar duct systems.

Insulation and Product Features
All busbars are applied epoxy resin. The joints are tin plated to minimize contact resistance and surface corrosion on the surface. Splice block conductors can be silver plated as an option.

Economic
Busbar trunking systems take up less space than cable trunking systems and have low installation costs.

BUSBAR FEATURES
*Voltage Drop
Due to its compact structure, it provides the most efficient transmission of power by minimizing the voltage drop due to its very low reactance.

*Joints
In external feeder busbars, the joints applied with a special gasket to prevent rain water from entering into it provide protection and smoothness in all conditions.

*Fitting
Elbows can be easily added with an additional block.

*Plug-In Points
Plug-ins are V2 (non-flammable), resistant to harsh environmental conditions and resistant to high temperatures. Sealed protection cover made of flame retardant certified material is IP 55. Jaws contact surfaces provide permeability thanks to the compression spring on the conductors.

HP-K Horizontal Montage
HP-K Vertical Montage

DTM Electrotechnic was established in 1977 to produce electrical panel and thermic relay DTM started manufacturing of busbar trunking system from 25A to 5000A with its experienced and high quality, skilled personals, since 2000.

READ MORE
CONTACT US


ADDRESS
Çatalmeşe Mah. Sultansuyu Cad. No:129, 34794 Alemdağ - Çekmeköy, İSTANBUL - TÜRKİYE

TELEPHONE
+90 216 429 51 74


E MAIL
info@dtmbusbar.com


FAX
+90 216 429 47 88

FOLLOW US ON SOCIAL MEDIA
You can follow us with the latest news
All Rights Reserved DTM Elektroteknik © 2024

TR
High Power Busbar Systems (400A / 6300A)
The Smartest Way to Distribute Power
HP-K SERIES

GENERAL FEATURES
Busbar trunking systems are sandwich systems compatible with complex low voltage energy distribution lines. Feeder and Plug-in types allow easy attachment to each other. They provide efficiency in low voltage distribution systems in industrial and commercial applications. Feeder and plug-in are produced with aluminum or copper conductors from 400 amps to 6300 amps. In the 3-pole or 4-pole full neutral configuration, the operating voltage is 1000 V. Standard production 3P+N+PE body grounding is 50% of the phase conductor. The case is produced as Aluminum. Standard production IP 55, IP 65 can be produced upon request.

General
It is used in places with high current requirements such as between transformer and panel, high service buildings, commercial centers, industrial facilities, military facilities, public buildings.

Sandwich Construction
Feeder and Plug-in busbars are sandwich type systems that are easy to assemble. Due to its structure, the voltage drop characteristics are at minimum and it provides a regular low reactive power factor. Construction channels are designed as aluminum profile and upper and lower covers are aluminum. Hysteresis currents and Eddy currents are minimized by spreading them in the aluminum channel. In cases where 2 or 3 conductors are used per phase in Feeder and Plug-in lengths, parallelization is made at the end of each phase. (In the change of phases). The body of the plug-in lengths has windows with lids that allow flat mounting and exit of tap-offs. Additional accessories used for the feeder can also be used in Plug-in types. Plug-in and Feeder types can be mounted together.

Full Enclosed Construction
Busbar systems have a fully closed design. This duct design does not reduce the electrical values and since there are no ventilation holes, the contact of the conductors with a foreign material is prevented. The heat dissipation spreads directly with the body close to the conductors.

Finish
RAL 7038
Electrostatic paint is applied in busbar duct systems.

Insulation and Product Features
All busbars are applied epoxy resin. The joints are tin plated to minimize contact resistance and surface corrosion on the surface. Splice block conductors can be silver plated as an option.

Economic
Busbar trunking systems take up less space than cable trunking systems and have low installation costs.

BUSBAR FEATURES
*Voltage Drop
Due to its compact structure, it provides the most efficient transmission of power by minimizing the voltage drop due to its very low reactance.

*Joints
In external feeder busbars, the joints applied with a special gasket to prevent rain water from entering into it provide protection and smoothness in all conditions.

*Fitting
Elbows can be easily added with an additional block.

*Plug-In Points
Plug-ins are V2 (non-flammable), resistant to harsh environmental conditions and resistant to high temperatures. Sealed protection cover made of flame retardant certified material is IP 55. Jaws contact surfaces provide permeability thanks to the compression spring on the conductors.

HP-K Horizontal Montage
HP-K Vertical Montage

DTM Electrotechnic was established in 1977 to produce electrical panel and thermic relay DTM started manufacturing of busbar trunking system from 25A to 5000A with its experienced and high quality, skilled personals, since 2000.

READ MORE
CONTACT US


ADDRESS
Çatalmeşe Mah. Sultansuyu Cad. No:129, 34794 Alemdağ - Çekmeköy, İSTANBUL - TÜRKİYE

TELEPHONE
+90 216 429 51 74

E MAIL
info@dtmbusbar.com

FAX
+90 216 429 47 88

FOLLOW US ON SOCIAL MEDIA
You can follow us with the latest news
All Rights Reserved DTM Elektroteknik © 2024